Tampilkan postingan dengan label screening. Tampilkan semua postingan
Tampilkan postingan dengan label screening. Tampilkan semua postingan

Rabu, 22 Juni 2011

Nosing around for staphylococci

In my last post about the newly described MRSA strains that carry the mecALGA251, I referred again to the “empty cassette variants” (or “mecA dropouts”) that are missed by commercial MRSA PCR tests that target the orfX gene but don’t contain mecA primers. I also mentioned that we’d soon be publishing our first year of experience with this. Well, here is the short report I was talking about, describing our ~8% rate of false positivity due to empty cassette variants, and characterizing the strains in question. We found substantial genetic diversity among the “drop-out” strains, meaning that the problem wasn’t due to the introduction of a single clone. When we tested these MSSA isolates using the newer GeneXpert MRSA/SA Nasal Assay (the “Nasal Complete” assay), they were correctly identified as S. aureus but not MRSA (this new assay has primers for the mecA gene). Even the “Nasal Complete” assay is susceptible to false positives, though, from the simultaneous presence of an MSSA and a methicillin-resistant coagulase-negative staphylococcus (MR-CoNS) in the same nose (the prevalence of MR-CoNS + MSSA co-colonization was 3.4% in one study). Indeed, the package insert describes a PPV of about 75% for the Nasal Complete—for MRSA, the 25% “false positives” divide equally between those for which culture was negative (which might reflect increased sensitivity of PCR) and those for which the culture grew only MSSA (which may reflect MR-CoNS/MSSA co-colonization). Who knew the nares would be such a vexing place for those who design and market PCR tests?

Senin, 25 Oktober 2010

Ctrl+F

…will bring up the “Find and Replace” tool in Microsoft Word. Illinois legislators, you may want to use this tool today, so you can get yourselves a shiny new law to deal with the latest emerging antimicrobial resistance threat.

Hint: you’ll want to find “MRSA”, and replace with “KPC”. Make sure to go to “search options” and click on “Match Case”, or you’ll mess it all up.

That should do it.

Links:
Illinois screening legislation
IDSA abstract on emergence of KPC-producers in Illinois
Chicago Tribune story

Kamis, 16 September 2010

Sensitivity of perianal swabs for MDR-GNR

Quick last abstract from ICAAC.  Graham Snyder et al. from Beth Israel Deaconess Medical Center in Boston enrolled 35 patients with known multidrug-resistant Gram-negative bacteria in clinical cultures (Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Enterobacter cloacae, Proteus mirabilis, and Morganella morganii). Each patient received a perianal swab. The sensitivity was 79%. It was a small study with the usual caveats.

Conflict of Interest: Graham was a medical resident that I worked and published with at Maryland.

link to medpage article